Chinese Journal of Stereotactic and Functional Neurosurgery ›› 2023, Vol. 36 ›› Issue (5): 309-315.DOI: 10.19854/j.cnki.1008-2425.2023.05.0010
Previous Articles Next Articles
Received:
2023-03-22
Online:
2023-10-25
Published:
2023-12-05
通讯作者:
孙伯民 sbm11224@rjh.com.cn
基金资助:
CLC Number:
刘杰, 马硕, 王宇涵, 潘宜新, 孙伯民. 脑深部电刺激术后磁共振成像:现状与进展[J]. 立体定向和功能性神经外科杂志, 2023, 36(5): 309-315.
[1] Lozano AM,Lipsman N.Probing and regulating dysfunctional circuits using deep brain stimulation[J].Neuron,2013,77(3):406~424. [2] Lozano AM,Lipsman N,Bergman H,et al.Deep brain stimulation:current challenges and future directions[J].Nat Rev Neurol,2019,15(3):148~160. [3] Sheth SA,Bijanki KR,Metzger B,et al.Deep brain stimulation for depression informed by intracranial recordings[J].Biological Psychiatry,2022,92(3):246~251. [4] Hariz M.My 25 stimulating years with DBS in parkinson's Disease[J].J Parkinsons Dis,2017,7(s1):S33~S41. [5] Lauterbur PC.Image formation by induced local interactions.Examples employing nuclear magnetic resonance.1973[J].Clin Orthop Relat Res,1989,(244):3~6. [6] Watson RE.Lessons Learned from MRI Safety Events[J].Current Radiology Reports,2015,3(10):37. [7] O'gorman RL,Jarosz JM,Samuel M,et al.CT/MR image fusion in the postoperative assessment of electrodes implanted for deep brain stimulation[J].Stereotactic and functional neurosurgery,2009,87(4):205~210. [8] Bot M,Van Den Munckhof P,Bakay R,et al.Accuracy of intraoperative computed tomography during deep brain stimulation procedures:comparison with postoperative magnetic resonance imaging[J].Stereotactic and Functional Neurosurgery,2017,95(3):183~188. [9] Merola A,Singh J,Reeves K,et al.New frontiers for deep brain stimulation:directionality,sensing technologies,remote programming,robotic stereotactic assistance,asleep procedures,and connectomics[J].Front Neurol,2021,12:694747. [10] Dormont D,Seidenwurm D,Galanaud D,et al.Neuroimaging and deep brain stimulation[J].AJNR Am J Neuroradiol,2010,31(1):15~23. [11] Falowski S,Safriel Y,Ryan MP,et al.The rate of magnetic resonance imaging in patients with deep brain stimulation[J].Stereotact Funct Neurosurg,2016,94(3):147~153. [12] Bove F,Mulas D,Cavallieri F,et al.Long-term outcomes (15 Years) after subthalamic nucleus deep brain stimulation in patients with Parkinson disease[J].Neurology,2021,97(3):e254. [13] Hancu I,Boutet A,Fiveland E,et al.On the (Non-)equivalency of monopolar and bipolar settings for deep brain stimulation fMRI studies of Parkinson's disease patients[J].J Magn Reson Imaging,2019,49(6):1736~1749. [14] Horn A,Wenzel G,Irmen F,et al.Deep brain stimulation induced normalization of the human functional connectome in Parkinson's disease[J].Brain,2019,142(10):3129~3143. [15] Hiss S,Hesselmann V,Hunsche S,et al.Intraoperative functional magnetic resonance imaging for monitoring the effect of deep brain stimulation in patients with obsessive-compulsive disorder[J].Stereotactic and functional neurosurgery,2015,93(1):30~37. [16] Miao J,Tantawi M,Koa V,et al.Use of Functional MRI in deep brain stimulation in parkinson's diseases:A systematic review[J].Front Neurol,2022,13:849918. [17] Loh A,Gwun D,Chow CT,et al.Probing responses to deep brain stimulation with functional magnetic resonance imaging[J].Brain Stimul,2022,15(3):683~694. [18] Vasques X,Tancu C,Cif L,et al.Cerebral magnetic resonance imaging feasibility in patients with implanted neurostimulation system for deep brain stimulation[J].The open magnetic resonance journal,2008,1(1). [19] Tagliai M,Jankovic J,Pagan F,et al.Safety of MRI in patients with implanted deep brain stimulation devices[J].Neuroimage,2009,47:T53~T57. [20] Siiegel J,Fuss G,Backens M,et al.Transient dystonia following magnetic resonance imaging in a patient with deep brain stimulation electrodes for the treatment of Parkinson disease.Case report[J].J Neurosurg,2003,99(4):772~774. [21] Zrinzo L,Yoshida F,Hariz MI,et al.Clinical safety of brain magnetic resonance imaging with implanted deep brain stimulation hardware:large case series and review of the literature[J].World Neurosurg,2011,76(1-2). [22] Henderson JM,Tkach J,Phillips M,et al.Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson's disease:case report[J].Neurosurgery,2005,57(5):E1063;discussion E. [23] Weise LM,Schneider GH,Kupsch A,et al.Postoperative MRI examinations in patients treated by deep brain stimulation using a non-standard protocol[J].Acta Neurochir (Wien),2010,152(12):2021~2027. [24] Larson PS,Richardson RM,Starr PA,et al.Magnetic resonance imaging of implanted deep brain stimulators:experience in a large series[J].Stereotactic and Functional Neurosurgery,2008,86(2). [25] Martin AJ.MRI in patients with deep brain stimulation electrodes:balancing risks and benefits[J].Radiology,2019,293(1):184~185. [26] Rezai AR,Phillips M,Baker KB,et al.Neurostimulation system used for deep brain stimulation (DBS):MR safety issues and implications of failing to follow safety recommendations[J].Invest Radiol,2004,39(5):300~303. [27] Boutet A,Chow CT,Narang K,et al.Improving safety of MRI in patients with deep brain stimulation devices[J].Radiology,2020,296(2):250~262. [28] Kalin R,Stanton MS.Current clinical issues for MRI scanning of pacemaker and defibrillator patients[J].Pace-Pacing And Clinical Electrophysiology,2005,28(4):326~328. [29] Oluigbo CO,Rezal AR.Magnetic resonance imaging safety of deep brain stimulator devices[J].Handb Clin Neurol,2013,116:73~76. [30] 张宇晶.脑深部电刺激装置的MRI相容性[J].中国医疗器械杂志,2013,37(4):244~247. [31] Winter L,Seifert F,Zilberti L,et al.MRI-related heating of implants and devices:A review[J].J Magn Reson Imaging,2021,53(6):1646~665. [32] Ruggera PS,Witters DM,Von Maltzahn G,et al.In vitro assessment of tissue heating near metallic medical implants by exposure to pulsed radio frequency diathermy[J].Phys Med Biol,2003,48(17):2919~2928. [33] Kazemivalipour E,Keil B,Vali A,et al.Reconfigurable MRI technology for low-SAR imaging of deep brain stimulation at 3T:Application in bilateral leads,fully-implanted systems,and surgically modified lead trajectories[J].NeuroImage,2019,199:18~29. [34] Medtronic.MRI guidelines for Medtronic deep brain stimulation systems[EB/OL].(2015-12-01)[2023-03-15].https://mriquestions.com/uploads/3/4/5/7/34572113/dbs_medtronics_contrib_228155.pdf [35] Scientific B.ImageReady MRI Guidelines for Boston Scientific Deep Brain Stimulation Systems[EB/OL].(2020-04-01)[2023-03-15].https://www.bostonscientific.com/content/dam/elabeling/nm/92328636-10B_MRI%20Guide_for_DB_StimSystem_IFU_MRI_OUS_ML_s.pdf [36] Medical SJ.MRI procedure information for St.Jude Medical MR conditional deep brain stimulation systems.[EB/OL].(2019-07-01)[2023-03-15].https://www.neuromodulation.abbott/us/en/healthcare-professionals/mri-support/mri-dbs-full-systems.html [37] Boutet A,Hancu I,Saha U,et al.3-tesla MRI of deep brain stimulation patients: Safety assessment of coils and pulse sequences[J].Journal of Neurosurgery,2020,132(2): 586-594. [38] Boston Scientific Receives FDA Approval For The Vercise Genus? Deep Brain Stimulation System[EB/OL] (2021-01-22)[2023-03-15]. https://news.bostonscientific.com/2021-01-22-Boston-Scientific-Receives-FDA-Approval-For-The-Vercise-Genus-TM-Deep-Brain-Stimulation-System. [39] G106R,安全3T 随心全身 3.0TMRI 全身核磁兼容[EB/OL] (2022-02-23)[2023-03-15].http://www.pinsmedical.com/nd.jsp?id=104. [40] Erhardt JB,Fuhrer E,Gruschke OG,et al.Should patients with brain implants undergo MRI?[J].J Neural Eng,2018,15(4):041002. [41] Bhusal B,Nguyen BT,Sanpitak PP,et al.Effect of device configuration and patient's body composition on the RF heating and nonsusceptibility artifact of deep brain stimulation implants during MRI at 1.5T and 3T[J].J Magn Reson Imaging,2021,53(2):599~610. [42] Bhusal B,Stockmann J,Guerin B,et al.Safety and image quality at 7T MRI for deep brain stimulation systems:Ex vivo study with lead-only and full-systems[J].PLoS One,2021,16(9):e0257077. [43] Vu J,Bhusal B,Nguyen BT,et al.A comparative study of RF heating of deep brain stimulation devices in vertical vs.horizontal MRI systems[J].PLoS One,2022,17(12):e0278187. [44] Elwassif MM,Kong Q,Vazquez M,et al.Bio-heat transfer model of deep brain stimulation-induced temperature changes[J].J Neural Eng,2006,3(4):306~315. [45] Elwassif MM,Datta A,Rahman A,et al.Temperature control at DBS electrodes using a heat sink:experimentally validated FEM model of DBS lead architecture[J].J Neural Eng,2012,9(4):046009. [46] Khadka N,HarmsenARMSEN i E,Lozano AM,et al.Bio-heat model of kilohertz-frequency deep brain stimulation increases brain tissue temperature[J].Neuromodulation,2020,23(4):489~495. [47] Fujimoto K,Angelone LM,Lucano E,et al.Radio-frequency safety assessment of stents in blood vessels during magnetic resonance imaging[J].Front Physiol,2018,9:1439. [48] Csrluccio G,Akgun C,Vaughan J T,et al.Temperature-based MRI safety simulations with a limited number of tissues[J].Magnetic Resonance In Medicine,2021,86(1):543~550. [49] Golestanirad L,Angelone LM,Kirsch J,et al.Reducing RF-induced heating near implanted leads through high-dielectric capacitive bleeding of current (CBLOC)[J].IEEE Trans Microw Theory Tech,2019,67(3):1265~1273. [50] Bonmassar G,Serano P.MRI-Induced heating of coils for microscopic magnetic stimulation at 1.5 Tesla:An Initial Study[J].Front Hum Neurosci,2020,14:53. [51] Jimenez-Shahed J.Device profile of the percept PC deep brain stimulation system for the treatment of Parkinson's disease and related disorders[J].Expert Rev Med Devices,2021,18(4):319~332. [52] Yang R.Effective methods to reduce the Rf-Induced heating for medical implants in mri[D].University of Houston,2020. [53] Zheng J,Yang R,Wang Q,et al.Reducing MRI RF-induced heating for the external fixation using capacitive structures[J].Phys Med Biol,2020,65(15):155017. [54] Sfondrini MF,Gallo S,Pascadopoli M,et al.Effect of magnetic resonance imaging at 1.5 T and 3 T on temperature and bond strength of orthodontic bands with welded tubes:An in vitro study[J].Materials (Basel),2023,16(2). [55] Boutet A,Rashid T,Hancu I,et al.Functional MRI safety and artifacts during deep brain stimulation:experience in 102 patients[J].Radiology,2019,293(1):174~183. [56] Li Y,Buch S,He N,et al.Imaging patients pre and post deep brain stimulation:Localization of the electrodes and their targets[J].Magn Reson Imaging,2021,75:34~44. [57] 李波姜,张锋,李路明.基于伪影模板的术后电极定位方法[J].清华大学学报(自然科学版),2017,57(9):952~957. [58] Nimbalkar S,Fuhrer E,Silva P,et al.Glassy carbon microelectrodes minimize induced voltages,mechanical vibrations,and artifacts in magnetic resonance imaging[J].Microsyst Nanoeng,2019,5:61. [59] Ashok Kumar N,Chauhan M,Kkndala SK,et al.Development and testing of implanted carbon electrodes for electromagnetic field mapping during neuromodulation[J].Magn Reson Med,2020,84(4):2103~2116. [60] Zhao S,Li G,Tong C,et al.Full activation pattern mapping by simultaneous deep brain stimulation and fMRI with graphene fiber electrodes[J].Nat Commun,2020,11(1):1788. [61] Kolaya E,Firstein BL.Deep brain stimulation:Challenges at the tissue-electrode interface and current solutions[J].Biotechnol Prog,2021,37(5):e3179. |
[1] | Zhang Jianping, Wu Rile, Bao JinGang. Effects and mechanism of different components of Ginkgo damol injection on neurological function and G-CSF and MAC-1 in subacute stroke mice [J]. Chinese Journal of Stereotactic and Functional Neurosurgery, 2023, 36(4): 217-222. |
[2] | . Analysis of the therapeutic effect of incision of the dorsal root of the spinal cord into the medullary region under multimodal neurophysiological monitoring in the treatment of pain after spinal cord injury [J]. Chinese Journal of Stereotactic and Functional Neurosurgery, 2023, 36(2): 86-89. |
[3] | Li Zheng, Xi Zhiyu, Bao Dejun, et al. A study assessing the relationship between the ratio of preoperative infarcted brain tissue volume to whole brain volume and the prognosis of patients with cerebral infarction after decompressive craniectomy [J]. Chinese Journal of Stereotactic and Functional Neurosurgery, 2022, 35(6): 343-349. |
[4] | Shi Jian, ZhangWeiwen, Yu Hao, et al. Application value of three-dimensional reconstruction combined with coordinate positioning method in clinical practice of neurosurgery [J]. Chinese Journal of Stereotactic and Functional Neurosurgery, 2022, 35(6): 350-353. |
[5] | Meng Qingyun, Shen Ping, Li Jing, et al. Analysis of clinicaland electrophysiologicalfeaturesin patients withnitrous oxide-induced neuropathy [J]. Chinese Journal of Stereotactic and Functional Neurosurgery, 2022, 35(6): 354-358. |
[6] | . [J]. Chinese Journal of Stereotactic and Functional Neurosurgery, 2022, 35(3): 188-192. |
[7] | . [J]. Chinese Journal of Stereotactic and Functional Neurosurgery, 2021, 34(5): 302-304. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||
Copyright © 2021 Chinese Journal of Stereotactic and Functional Neurosurgery
Address: Anyuan Road, Shuangqiao District, Chengde City, Hebei Province. Zip code: 230036 Telephone: 0551-62282374
he system is designed and developed by Beijing magtec Technology Development Co., Ltd. with technical support: support@magtech.com.cn